Системы теплоэнергосберегающего оборудования и кондиционирования
 +7 921 845-12-36
  КАТАЛОГ ПРОДУКЦИИ

Взрывозащищенные инверторы

Взрывозащищенные инверторы - изображение товара

1×Combination Explosion-proof Inverter

 

Rated voltage

6kv/10kv -15%—+10%(rated load)

Phase NO./Frequency

3/50HZ ±10%

AC drive input

Rated voltage

2×1903V -15%—+10%(rated load)

Phase NO./Frequency

6/50HZ ±10%

AC drive output

Rated power

BPJV3-3×2200/3.3

BPJV3-3×1600/3.3

BPJV3-3×1250/3.3

BPJV3-3×855/3.3

Rated voltage

Sine-wave 0v—3.3kv continuously

adjustable

Overload capability

Classical 150% 1min (120%-250% optional )

Frequency

0—50Hz(0—66Hz)

control

Input/Output interface

16 digital input terminals

16 digital output terminals

Communication interface

Earth net/CAN/Profibus/RS485

Signal isolation mode

Optical isolation

Control signal transmission

Fiber transmission

Efficiency

>97%

environment

Vibration

10-150Hz ,below 0.5g

Storage conditions

-20—70℃

Protection class

IP54,Exdl

2×Combination Explosion-proof Inverter

 

Rated voltage

6kv/10kv -15%—+10%(rated load)

Phase NO./Frequency

3/50HZ ±10%

AC drive input

Rated voltage

2×1903V -15%—+10%(rated load)

Phase NO./Frequency

6/50HZ ±10%

AC drive output

Rated power

BPJV3-3×2200/3.3

BPJV3-3×1600/3.3

BPJV3-3×1250/3.3

BPJV3-3×855/3.3

Rated voltage

Sine-wave 0v—3.3kv continuously

adjustable

Overload capability

Classical 150% 1min (120%-250% optional )

Frequency

0—50Hz(0—66Hz)

control

Input/Output interface

16 digital input terminals

16 digital output terminals

Communication interface

Earth net/CAN/Profibus/RS485

Signal isolation mode

Optical isolation

Control signal transmission

Fiber transmission

Efficiency

>97%

environment

Vibration

10-150Hz ,below 0.5g

Storage conditions

-20—70℃

Protection class

IP54,Exdl

Three inverters explosion-proof medium-voltage combination AC drive

 

Rated voltage

6kv/10kv -15%—+10%(rated load)

Phase NO./Frequency

3/50HZ ±10%

AC drive input

Rated voltage

2×1903V -15%—+10%(rated load)

Phase NO./Frequency

6/50HZ ±10%

AC drive output

Rated power

BPJV3-3×2200/3.3

BPJV3-3×1600/3.3

BPJV3-3×1250/3.3

BPJV3-3×855/3.3

Rated voltage

Sine-wave 0v—3.3kv continuously

adjustable

Overload capability

Classical 150% 1min (120%-250% optional )

Frequency

0—50Hz(0—66Hz)

control

Input/Output interface

16 digital input terminals

16 digital output terminals

Communication interface

Earth net/CAN/Profibus/RS485

Signal isolation mode